Microtel DialStat (No Fault Indicators) Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Microtel DialStat (No Fault Indicators). Microtel DialStat (No Fault Indicators) User Manual [en] [it] [de] [fr] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
MICROTEL DialStat
TM
i
Microtel DialStat
TM
Operating Manual
1 September 1998
Rev. B
Proprietary Notice:
This document and the subject matter hereto are the
property of MICROTEL, Inc. and shall not be reproduced or copied or used for the
purpose of manufacturing or sale of apparatus, except by written permission of
MICROTEL.
MICROTEL
11725 Sunbelt Court
Suite C
Baton Rouge, LA 70809
225-303-0436
Fax: 225-303-0568
www.microtel-inc.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 30 31

Podsumowanie treści

Strona 1 - MICROTEL

MICROTEL DialStatTM i Microtel DialStatTM Operating Manual 1 September 1998 Rev. B Proprietary Notice: This document and the subj

Strona 2

MICROTEL DialStatTM 6 How can I Make an Alarm Sound in the Vicinity of the Dialer? The local summary alarm contacts will be de-energized (opened)

Strona 3 - LIST OF ILLUSTRATIONS

MICROTEL DialStatTM 7CHAPTER 2 - Installation nstallation of the DialStatTM involves several, simple steps. This chapter outlines the physical

Strona 4 - DialStat

MICROTEL DialStatTM 8 Step Two - Telephone Connections include the external phone line for call-outs and the optional local telephone connection

Strona 5 - INTRODUCTION

MICROTEL DialStatTM 9Step Three - Connect External Input/Output to the Dialer Each Fault input has a corresponding terminal (1 - 4), and there ar

Strona 6

MICROTEL DialStatTM 10 Quick Start Procedure This procedure outlines the steps to get the DialStatTM dialer operating in a typical manner with a m

Strona 7 - Dialer

MICROTEL DialStatTM 11 Individual Channel Alarm Messages: z Enter **c1 to record an alarm message for a specific I/O channel. (c = 1 to 4 for th

Strona 8

MICROTEL DialStatTM 12 CHAPTER 3 - Operation his chapter, divided into Configuration and Operation sections, will explain how to configure the D

Strona 9

MICROTEL DialStatTM 13Configuration The configuration commands described in this section modify basic dialer operation and store information about

Strona 10 - MICROTEL DialStat

MICROTEL DialStatTM 14 z Answer Delay The number of rings the dialer will see before answering an incoming call. *02 Review answer delay **02nn

Strona 11 - CHAPTER 2 - Installation

MICROTEL DialStatTM 15Configuring Fault Inputs The DialStatTM features true modularity—Fault input channels operate completely independently of e

Strona 12

MICROTEL DialStatTM ii Record of Changes Rev. Date Description of Changes By - 9/1/ 98 Original Release Be

Strona 13

MICROTEL DialStatTM 16 NOTE: If C=5, the Power Fault channel, the response is: Example Command: **531 Response: Power fault channel is READY C

Strona 14 - Quick Start Procedure

MICROTEL DialStatTM 17Alarm Acknowledgment When DialStatTM calls you, you may wish to respond to the call differently depending on what type of al

Strona 15

MICROTEL DialStatTM 18 CHAPTER 4 - Maintenance/Troubleshooting he DialStatTM Dialer is built to require minimal maintenance. Only the system bat

Strona 16 - CHAPTER 3 - Operation

MICROTEL DialStatTM 19TROUBLESHOOTING: Symptom: Unable to place telephone calls (Line LED comes on but no ring at called telephone number).

Strona 17 - Configuration

MICROTEL DialStatTM 20 CHAPTER 5 - Advanced Topics his chapter details more advanced topics concerning the setup, configuration, and operation of

Strona 18

MICROTEL DialStatTM 21APPENDICES APPENDIX A: Technical Specifications A.1 Communications Phone Interface: FCC 68 Registration Number:

Strona 19 - Configuring Fault Inputs

MICROTEL DialStatTM 22 A.4 Environmental Temperature: 20°F to 130°F operating 0°F to 130°F storage Humidity: 0-95% RH, Noncondensing

Strona 20 - Operations

MICROTEL DialStatTM 23A.7 Fault Inputs Type: Isolated Dry Contact, Normal Open or Normal Closed, Non-Latched. Sensing frequency: 1 Hz

Strona 21 - Alarm Acknowledgment

MICROTEL DialStatTM 24 APPENDIX B: Glossary of Dialer Terminology Acknowledge Stops the dialer from placing additional calls concerning an ala

Strona 22 - FUSE: DialStat

MICROTEL DialStatTM 25APPENDIX C: FCC Requirements This equipment complies with Part 68 of the FCC rules. On the side of the DialStat metal case

Strona 23 - TROUBLESHOOTING:

MICROTEL DialStatTM iiiTABLE OF CONTENTS INTRODUCTION 1 CHAPTER 1 - DESCRIPTION OF THE DIALSTATTM DIALER 3 CHAPTER 2 - INSTALLATION 7 Quick St

Strona 24 - CHAPTER 5 - Advanced Topics

MICROTEL DialStatTM 26 APPENDIX D: DialStatTM Command Summary *00 Report system status *01 **01~ Voice system name (10

Strona 25 - APPENDICES

MICROTEL DialStatTM 27 Figure 4 Mounting Dimensions

Strona 26

MICROTEL DialStatTM iv

Strona 27

MICROTEL DialStatTM 1INTRODUCTION hank you for choosing the Microtel DialStatTM Dialer to implement your remote alarm monitoring solution. You hav

Strona 28

MICROTEL DialStatTM 2 Figure 1: Controls and Indicators

Strona 29

MICROTEL DialStatTM 3CHAPTER 1 - Description Of The DialStatTM Dialer he DialStatTM is a small, rugged, and simple, but powerful, device which e

Strona 30 - Command Summary

MICROTEL DialStatTM 4 How Does the Dialer Work? This section provides a simple theory of operation by asking a few questions about typical use of t

Strona 31

MICROTEL DialStatTM 5These include tone/pulse selection dialing, pauses, auto acknowledgment of an alarm call-out, dial '*' or '#&ap