MicroWin 2000EX
Operating Manual
September, 2002
MicroWin 2000EX
Rev B
For S1000EX Dialer
Proprietary Notice:
This document and the subject matter hereto are the property
of MICROTEL, Inc. and shall not be reproduced or copied or used for the purpose of
manufacturing or sale of apparatus, except by written permission of MICROTEL.
MICROTEL
206 West Judge Perez Drive
Chalmette, Louisiana 70043
504/276-0571
Fax: 504/276-0574
www.microtel-inc.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 62 63

Podsumowanie treści

Strona 1 - MICROTEL

MicroWin 2000EX Operating Manual September, 2002 MicroWin 2000EX Rev B For S1000EX Dialer Proprietary Notice: This document and the

Strona 2 - - ii

MicroWin 2000EX Manual 4Software Installation Windows 95 / 98 / ME / XP / NT / Before installing the software, check to make sure that all other pro

Strona 3 - Record of Changes

MicroWin 2000EX Manual 5Starting MicroWin 2000EX Serial Number The first time MicroWin 2000EX is started, it will prompt you to enter the serial num

Strona 4 - - iv

MicroWin 2000EX Manual 6Menu Options Menu Bar This is located on the top of a form right under the title bar. The following are brief descriptions

Strona 5

MicroWin 2000EX Manual 7Format All Channels Displays all channels 1 thru 41. Used Channels Displays only configured channels. View Archive Di

Strona 6 - - vi

MicroWin 2000EX Manual 8Tools Log Modem Selecting this will create a file named Dial_Debug.txt that will log all MicroWin 2000EX actions. The fi

Strona 7 - Introduction

MicroWin 2000EX Manual 9 Edit MicroWin Enable or Disable Auto Answer or Callouts. Select Com Port

Strona 8 - Dialer Requirements

MicroWin 2000EX Manual 10Setup MicroWin 2000EX to Connect to a S1000EX MicroWin 2000Ex can connect to a S1000EX in two different ways, Modem or Loca

Strona 9 - System Requirements

MicroWin 2000EX Manual 11NOTE: When selecting the Com Type MicroWin 2000EX will show default settings on the Setup COM Port form. In most cases th

Strona 10 - Software Installation

MicroWin 2000EX Manual 12Init String 1: Default: AT&F&C1&M0 Init String 2: Default: <Blank> Init String 3: Default: <Blank&

Strona 11 - Exiting MicroWin 2000EX

MicroWin 2000EX Manual 13 Connect MicroWin 2000EX to a S1000EX Select the project by clicking in the blue background of the project’s title bar. To

Strona 12 - Menu Options

MicroWin 2000EX Manual - ii -

Strona 13

MicroWin 2000EX Manual 14Realtime Data Form ACK ALL When MicroWin 2000EX connects to a dialer depressing this button on the real time page acknow

Strona 14

MicroWin 2000EX Manual 15 The channel is setup to follow another channel’s state. Its state depends on the channel that it’s following. Type This t

Strona 15

MicroWin 2000EX Manual 16Audible Alert When a dialer is setup to call MicroWin 2000EX to announce an alarm condition, a horn is heard along with the

Strona 16

MicroWin 2000EX Manual 17 Editing a Dialer Configuration This section will go over how to edit an S1000EX dialer configuration. It will show how to

Strona 17

MicroWin 2000EX Manual 18Edit Dialer Menu The different sections of a configuration include the System Setup, Calendar Setup, Telephone Setup, Po

Strona 18

MicroWin 2000EX Manual 19System Setup On the Edit Dialer tab, click the System Setup button. The System Menu will be displayed. In the title bar

Strona 19

MicroWin 2000EX Manual 20In 10ths of a second, this is the delay time that will occur from the time a dialer command is typed in with a touch-tone p

Strona 20

MicroWin 2000EX Manual 21 Save / Default / Restore / Cancel At the bottom of the form, there are the standard Save/Default/Restore/Cancel buttons.

Strona 21

MicroWin 2000EX Manual 22Point Setup On the Edit Dialer tab,, click the Point Setup button. The Point Menu will be displayed. In the title bar,

Strona 22

MicroWin 2000EX Manual 23 This form is used to edit this point’s settings. Point Number # Tells what I/O Point is currently being edited. Name Th

Strona 23

MicroWin 2000EX Manual - iii - Record of Changes Rev Date Changes Submitted By - January 2002 Original Document Berk Ehret A March 2002 Sheet

Strona 24

MicroWin 2000EX Manual 24Whenever an Input Type is programmed to Call on an alarm condition and such a condition occurs, this channel will try to re

Strona 25

MicroWin 2000EX Manual 25A Alarm channel will cause alarm call outs when an alarm conditions occurs. If the alarm condition clears without being ac

Strona 26

MicroWin 2000EX Manual 26 Analog Output To set the output state of the Analog Output Channel you must be connected. Select the button in the State

Strona 27

MicroWin 2000EX Manual 27 The following describes the five types of Follow Channels: 1) Follow Channel’s State Whenever the followed channel’s sta

Strona 28

MicroWin 2000EX Manual 28 For all Digital Channel Types, the administrator has the ability to set how a channel’s state will appear when reading an

Strona 29 - Input Types

MicroWin 2000EX Manual 29be used to monitor oil temperatures, barring temperatures, etc. The temperature range is -50° F to 350° F. For more infor

Strona 30

MicroWin 2000EX Manual 30Calendar Setup On the Edit Dialer tab, click the Calendar Setup button. The Calendar Menu will be displayed. In the tit

Strona 31 - User Controlled Output Types

MicroWin 2000EX Manual 31There is an easy way to set Every Day or just Weekdays to a particular call at time. Simply enter the time in the box show

Strona 32

MicroWin 2000EX Manual 32Archiving Setup On the Edit Dialer tab, click the Archiving Setup button. This will display the Archive Menu. This fo

Strona 33

MicroWin 2000EX Manual 33be transferred to MicroWin 2000EX. Once in MicroWin 2000EX, the data can be reviewed, printed, etc. What is an Archive? A

Strona 34

MicroWin 2000EX Manual - iv -

Strona 35

MicroWin 2000EX Manual 34 This is a useful type of archiving when all the operator is concerned with is finding out when certain events occur. For

Strona 36

MicroWin 2000EX Manual 35If the Max Archives goes down, this channel will only keep the newest archives to fill in the new channel archive size. Th

Strona 37

MicroWin 2000EX Manual 36Telephone Numbers On the Edit Dialer tab, click the Telephone Setup button. The Phone Number Menu will be displayed. In

Strona 38

MicroWin 2000EX Manual 37 This form is used to edit the phone number settings. Phone Number Tells what telephone number is currently being edited.

Strona 39

MicroWin 2000EX Manual 38Send Config After editing a new configuration or making changes to a old one these changes must be sent to the S1000EX. M

Strona 40

MicroWin 2000EX Manual 39 Select the check boxes for the Send Selection choices, then select Send.

Strona 41

MicroWin 2000EX Manual 40Get Config MicroWin 2000EX can retrieve any and all settings that particular project has except the voice messages. If you

Strona 42

MicroWin 2000EX Manual 41After the Access Code is accepted the Upload from Dialer form will be shown. Select the check boxes for the Receive Sele

Strona 43

MicroWin 2000EX Manual 42 Setup S1000EX to Call MicroWin 2000EX If you want a particular dialer to call a MicroWin 2000EX to report some alarm condi

Strona 44 - Send Config

MicroWin 2000EX Manual 43Archives What is Archiving? Archiving is the ability to collect specific events as they occur. This data can later be used

Strona 45

MicroWin 2000EX Manual - v - Table Of Contents Introduction 1 Dialer Requirements 2 Upgrading a Series 1000 Dialer 2 System Requirements 3 Soft

Strona 46 - Get Config

MicroWin 2000EX Manual 44The Status Window will show the transfer progress. Once the archives have been retrieved from a dialer, they are removed f

Strona 47

MicroWin 2000EX Manual 45Click on the View Archives button for the desired channel. The Archive View form displays the archives for a particular

Strona 48

MicroWin 2000EX Manual 46 Select/Unselect All Selects or unselects all records that are currently viewed, respectively. Print Selected Archives Ta

Strona 49 - Archives

MicroWin 2000EX Manual 47 Selecting a Time Frame Once a number of records have been downloaded to the database from the dialer, searching for inform

Strona 50

MicroWin 2000EX Manual 48Delete Selected, this feature will delete all selected records. Copy to Clipboard, after selecting the records of choice,

Strona 51

MicroWin 2000EX Manual 49Snapshots What is an Snapshot? While an entry and dialer are connected, a recorded snapshot can be taken. An entry can be

Strona 52

MicroWin 2000EX Manual 50 Snapshot Menu Actions When a snapshot is taken, it is first put into the Unselected Snapshots list. This list contains

Strona 53

MicroWin 2000EX Manual 51 This form allows the user to view the selected snapshot data. The snapshot viewed corresponds to the Time Stamp at the t

Strona 54

MicroWin 2000EX Manual 52Polling Mode MicroWin 2000EX can be set to automatically call any dialer and collect Snapshots and Archives. To use the P

Strona 55 - Snapshots

MicroWin 2000EX Manual 53received. After it is finished, if no other transfer actions are currently set, MicroWin 2000EX will disconnect from the di

Strona 56

MicroWin 2000EX Manual - vi -

Strona 57

MicroWin 2000EX Manual 54Appendix A – Troubleshooting This section could be looked at when Com Errors are occurring. Problem: When I try to connec

Strona 58 - Polling Mode

MicroWin 2000EX Manual 55Appendix B – Important Things to Remember Enabling/Disabling an projects’s automatic Snapshots and Archives only changes h

Strona 59

MicroWin 2000EX Manual 56Appendix C – Answers to Frequently Asked Questions Q. I have several dialers in my system that are setup to call MicroWin

Strona 60 - Appendix A – Troubleshooting

MicroWin 2000EX Manual 57USERS MANUAL ERROR REPORT Error Description(s): Reports of any errors found in the manual are apprec

Strona 61

MicroWin 2000EX Manual 1Introduction Thank you for choosing MicroWin 2000EX. MicroWin 2000EX is a software supplement for Microtel Series 1000EX d

Strona 62

MicroWin 2000EX Manual 2Dialer Requirements MicroWin 2000EX software will only work with Series 1000EX dialers. Upgrading a Series 1000 Dialer A S1

Strona 63

MicroWin 2000EX Manual 3System Requirements • Windows 95, Windows 98, Windows Me, Windows NT, and Windows XP Compatible • 32 Megabytes of RAM • A